LG heat pump

KUSXB601A

Ducted split systemVariable-speed (inverter)ENERGY STAR cold-climateENERGY STAR Most Efficient (some pairings)

The LG KUSXB601A is a ducted split system heat pump outdoor unit with a rated cooling capacity of 52,500 BTU/h (about 4.5 tons) and a variable-speed (inverter) compressor running on R-32 refrigerant. ENERGY STAR lists 6 certified indoor-unit pairings for it. In cold weather it still delivers 45,000 BTU/h at 5°F — 80% of its 47°F output, above the 76% median across the 308 models we track (better than 57% of them). Its HSPF2 of 9.4 is higher than 51% of models in our database, and its best certified SEER2 of 17.5 beats 44%.

Our take in 30 seconds

Best for: mixed climates with occasional hard freezes

Strengths

  • Variable-speed compressor: quieter, steadier temperatures and better humidity control
  • Uses newer, lower-impact R-32 refrigerant

Good to know

  • No notable drawbacks in the certified data.
Est. yearly cost
$2,436
U.S. average rates
SEER2
15.2–17.5
Cooling efficiency
HSPF2
9.4
Top 49% heating efficiency
Heat kept at 5°F
80%
Median is 76%
Advertisement

Running-cost calculator

Pre-filled with EIA prices · edit any field
Estimated annual cost
—
Heating
—
Cooling
—

Uses the base certified SEER2 (15.2) and HSPF2 (9.4). Assumes the unit is correctly sized. How we calculate.

Heating capacity as it gets colder

A heat pump's output falls as outdoor temperature drops. This is the certified heat output of the LG KUSXB601A at the three ENERGY STAR test temperatures (cooling capacity is 52,500 BTU/h for reference).

47°F
56,500 BTU/h
17°F
36,400 BTU/h
5°F
45,000 BTU/h

Retention at 17°F: 64% · at 5°F: 80%. Learn how to use these numbers in our cold-climate guide.

Estimated running cost in every state

Same unit, very different bills: from about $1,431 a year in Louisiana to $5,462 in Maine, driven by local electricity prices and how much heating or cooling the climate needs. Click a column to sort.

StatePriceHeatingCoolingTotal / yr
Louisiana12.87¢$541$889$1,431
Florida14.99¢$405$1,243$1,648
Washington14.63¢$1,495$177$1,672
Mississippi14.43¢$781$897$1,678
Nevada12.72¢$917$791$1,708
Tennessee13.42¢$1,129$603$1,732
Arizona15.05¢$633$1,144$1,777
Oregon15.92¢$1,531$247$1,778
North Carolina14.95¢$1,168$671$1,839
Kentucky13.80¢$1,327$524$1,851
Arkansas14.37¢$1,123$744$1,867
South Carolina15.76¢$1,042$871$1,913
Georgia15.90¢$1,051$879$1,930
Utah13.31¢$1,520$414$1,934
Texas15.91¢$861$1,099$1,960
Alabama16.33¢$1,080$902$1,982
Idaho13.37¢$1,688$323$2,011
Oklahoma14.82¢$1,247$768$2,015
New Mexico16.51¢$1,489$570$2,059
Nebraska13.54¢$1,709$421$2,130
West Virginia16.31¢$1,765$451$2,215
Missouri16.02¢$1,637$609$2,246
Virginia17.64¢$1,590$670$2,261
Kansas15.47¢$1,674$588$2,261
Wyoming14.43¢$2,168$249$2,418
Colorado17.17¢$2,064$415$2,479
North Dakota13.31¢$2,320$207$2,527
Indiana17.02¢$2,046$500$2,546
Delaware18.70¢$1,911$646$2,557
Montana15.57¢$2,340$242$2,582
South Dakota15.15¢$2,277$340$2,617
California29.75¢$1,609$1,028$2,637
Iowa17.06¢$2,358$442$2,800
Ohio19.38¢$2,330$536$2,865
Maryland21.40¢$2,187$739$2,926
Illinois19.32¢$2,439$534$2,972
Minnesota17.20¢$2,791$327$3,118
Pennsylvania21.77¢$2,617$602$3,219
Wisconsin19.41¢$2,917$402$3,319
New Jersey24.61¢$2,663$765$3,428
District of Columbia25.98¢$2,499$987$3,486
Connecticut24.51¢$3,241$550$3,791
Michigan22.99¢$3,316$476$3,793
Vermont23.84¢$3,726$371$4,096
Rhode Island28.18¢$3,726$584$4,310
Hawaii47.18¢$142$4,237$4,379
New York28.65¢$3,789$643$4,432
New Hampshire27.64¢$4,153$477$4,631
Massachusetts30.48¢$4,214$632$4,845
Alaska29.41¢$5,303$102$5,405
Maine32.11¢$5,018$444$5,462
Advertisement

Similar-size alternatives

Other ducted split system units within ±15% of this model's cooling capacity, sorted by efficiency. Cost difference is versus the LG KUSXB601A at U.S.-average rates.

ModelCooling BTU/hSEER2HSPF25°F keptEst. yearly cost
Ruud UP19AY48AJVC45,50018–191092%$1,827 (−$609)Compare
Gree GUD60W2/NHE-D(U)53,00016–1910.5100%$2,156 (−$280)Compare
Heil B5H3V48*K*AAA*46,50020–239.576%$1,963 (−$473)Compare
Tempstar T5H3V48*K*AAA*46,50019.5–239.572%$2,113 (−$324)Compare
Rheem RD18AY60AJVC52,00016–181066%$2,393 (−$44)Compare
Carrier 27VPA948A*030*49,50015.2–191075%$2,249 (−$188)Compare

Full specifications

BrandLG
Outdoor modelKUSXB601A
Certified byLG Electronics, Inc.
Product typeDucted split system
CompressorVariable-speed (inverter)
RefrigerantR-32
Cooling capacity52,500 BTU/h
Nominal size4.5 tons
SEER2 (certified range)15.2 – 17.5
EER2 (best)12
HSPF2 (best)9.4
Heating capacity @ 47°F56,500 BTU/h
Heating capacity @ 17°F36,400 BTU/h
Heating capacity @ 5°F45,000 BTU/h
COP @ 5°F2
ENERGY STAR cold-climateYes
Certified indoor pairings6
Latest certification2026-04

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), retrieved November 7, 2026. Capacities and HSPF2 are the highest values across certified pairings; confirm your exact system's AHRI reference number with your installer.

Frequently asked questions

How much does the LG KUSXB601A cost to run per year?

At the U.S. average residential electricity price of 18.16¢/kWh and typical national heating and cooling hours, we estimate about $2,436 per year ($1,746 heating, $690 cooling). It ranges from about $1,431 in Louisiana to $5,462 in Maine.

Does the LG KUSXB601A work in cold weather?

Yes. It is ENERGY STAR cold-climate certified and delivers 45,000 BTU/h at 5°F, 80% of its 47°F capacity, with a COP of 2 at 5°F.

What size is the LG KUSXB601A?

It is rated at 52,500 BTU/h of cooling, roughly 4.5 tons, and 56,500 BTU/h of heating at 47°F. Proper sizing should be confirmed with a Manual J load calculation.

Advertisement