Friedrich heat pump

FWP15AZ36AJ2N

Ducted split systemTwo-stage

The Friedrich FWP15AZ36AJ2N is a ducted split system heat pump outdoor unit with a rated cooling capacity of 34,200 BTU/h (about 3 tons) and a two-stage compressor running on R-410A refrigerant. ENERGY STAR lists 38 certified indoor-unit pairings for it. In cold weather it still delivers 19,900 BTU/h at 5°F — 58% of its 47°F output, below the 76% median across the 308 models we track (better than 30% of them). Its HSPF2 of 8.1 is higher than 17% of models in our database, and its best certified SEER2 of 15.2 beats 6%.

Our take in 30 seconds

Best for: mild climates or homes with backup heat

Strengths

  • Meets ENERGY STAR efficiency requirements.

Good to know

  • Only 58% of its heat output remains at 5°F; plan on backup heat in hard freezes
  • Heating efficiency (HSPF2 8.1) is in the lower third of models
  • Uses R-410A, a refrigerant being phased down; future service may cost more
Est. yearly cost
$1,676
U.S. average rates
SEER2
15.2–15.2
Cooling efficiency
HSPF2
8.1
Top 83% heating efficiency
Heat kept at 5°F
58%
Median is 76%
Advertisement

Running-cost calculator

Pre-filled with EIA prices · edit any field
Estimated annual cost
—
Heating
—
Cooling
—

Uses the base certified SEER2 (15.2) and HSPF2 (8.1). Assumes the unit is correctly sized. How we calculate.

Heating capacity as it gets colder

A heat pump's output falls as outdoor temperature drops. This is the certified heat output of the Friedrich FWP15AZ36AJ2N at the three ENERGY STAR test temperatures (cooling capacity is 34,200 BTU/h for reference).

47°F
34,200 BTU/h
17°F
24,800 BTU/h
5°F
19,900 BTU/h

Retention at 17°F: 73% · at 5°F: 58%. Learn how to use these numbers in our cold-climate guide.

Estimated running cost in every state

Same unit, very different bills: from about $960 a year in Louisiana to $3,814 in Maine, driven by local electricity prices and how much heating or cooling the climate needs. Click a column to sort.

StatePriceHeatingCoolingTotal / yr
Louisiana12.87¢$380$579$960
Florida14.99¢$285$809$1,094
Mississippi14.43¢$548$584$1,133
Nevada12.72¢$644$515$1,160
Washington14.63¢$1,050$115$1,165
Tennessee13.42¢$793$393$1,186
Arizona15.05¢$445$745$1,190
Oregon15.92¢$1,075$161$1,237
North Carolina14.95¢$821$437$1,258
Arkansas14.37¢$789$485$1,274
Kentucky13.80¢$932$342$1,274
South Carolina15.76¢$732$567$1,299
Georgia15.90¢$738$572$1,311
Texas15.91¢$605$716$1,321
Utah13.31¢$1,068$270$1,337
Alabama16.33¢$758$588$1,346
Oklahoma14.82¢$876$500$1,376
Idaho13.37¢$1,185$211$1,396
New Mexico16.51¢$1,046$371$1,417
Nebraska13.54¢$1,201$274$1,475
West Virginia16.31¢$1,240$294$1,533
Missouri16.02¢$1,150$396$1,546
Virginia17.64¢$1,117$437$1,554
Kansas15.47¢$1,176$383$1,559
Wyoming14.43¢$1,523$162$1,686
Colorado17.17¢$1,450$270$1,720
Indiana17.02¢$1,437$326$1,763
Delaware18.70¢$1,342$421$1,763
North Dakota13.31¢$1,630$135$1,764
California29.75¢$1,130$669$1,800
Montana15.57¢$1,644$158$1,801
South Dakota15.15¢$1,599$222$1,821
Iowa17.06¢$1,657$288$1,945
Ohio19.38¢$1,637$349$1,985
Maryland21.40¢$1,536$482$2,018
Illinois19.32¢$1,713$348$2,061
Minnesota17.20¢$1,961$213$2,174
Pennsylvania21.77¢$1,838$392$2,230
Wisconsin19.41¢$2,049$262$2,311
New Jersey24.61¢$1,870$498$2,369
District of Columbia25.98¢$1,755$643$2,398
Connecticut24.51¢$2,277$358$2,635
Michigan22.99¢$2,330$310$2,640
Vermont23.84¢$2,617$241$2,858
Hawaii47.18¢$100$2,760$2,860
Rhode Island28.18¢$2,618$380$2,998
New York28.65¢$2,661$419$3,080
New Hampshire27.64¢$2,918$311$3,229
Massachusetts30.48¢$2,960$411$3,371
Alaska29.41¢$3,725$66$3,791
Maine32.11¢$3,525$289$3,814
Advertisement

Similar-size alternatives

Other ducted split system units within ±15% of this model's cooling capacity, sorted by efficiency. Cost difference is versus the Friedrich FWP15AZ36AJ2N at U.S.-average rates.

ModelCooling BTU/hSEER2HSPF25°F keptEst. yearly cost
Ruud UP19AY36AJVC34,20019–211087%$1,353 (−$323)Compare
Payne 37MUHAQ30AA330,00015.3–17.510.898%$1,306 (−$370)Compare
Midea MO1HE-H30B-2A30,00015.2–17.510.898%$1,309 (−$367)Compare
Bryant 37MUHAQ36AA336,00015.8–1810.3103%$1,527 (−$149)Compare
Daikin DH9VSA361CA*34,20016.9–2110100%$1,398 (−$278)Compare
Panasonic CU-HM36BAHU36,00015.6–17.410.3103%$1,533 (−$143)Compare

Full specifications

BrandFriedrich
Outdoor modelFWP15AZ36AJ2N
Certified byRheem Sales Company, Inc.
Product typeDucted split system
CompressorTwo-stage
RefrigerantR-410A
Cooling capacity34,200 BTU/h
Nominal size3 tons
SEER2 (certified range)15.2 – 15.2
EER2 (best)11.7
HSPF2 (best)8.1
Heating capacity @ 47°F34,200 BTU/h
Heating capacity @ 17°F24,800 BTU/h
Heating capacity @ 5°F19,900 BTU/h
COP @ 5°F2.3
ENERGY STAR cold-climateNo
Certified indoor pairings38
Latest certification2026-06

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), retrieved November 7, 2026. Capacities and HSPF2 are the highest values across certified pairings; confirm your exact system's AHRI reference number with your installer.

Frequently asked questions

How much does the Friedrich FWP15AZ36AJ2N cost to run per year?

At the U.S. average residential electricity price of 18.16¢/kWh and typical national heating and cooling hours, we estimate about $1,676 per year ($1,227 heating, $449 cooling). It ranges from about $960 in Louisiana to $3,814 in Maine.

Does the Friedrich FWP15AZ36AJ2N work in cold weather?

It is not ENERGY STAR cold-climate certified. It delivers 19,900 BTU/h at 5°F (58% of its 47°F capacity), so in very cold climates expect more reliance on backup heat.

What size is the Friedrich FWP15AZ36AJ2N?

It is rated at 34,200 BTU/h of cooling, roughly 3 tons, and 34,200 BTU/h of heating at 47°F. Proper sizing should be confirmed with a Manual J load calculation.

Advertisement