Bryant heat pump

37MUHAQ36AA3

Ducted split systemVariable-speed (inverter)ENERGY STAR cold-climateENERGY STAR Most Efficient (some pairings)

The Bryant 37MUHAQ36AA3 is a ducted split system heat pump outdoor unit with a rated cooling capacity of 36,000 BTU/h (about 3 tons) and a variable-speed (inverter) compressor running on R-454B refrigerant. ENERGY STAR lists 8 certified indoor-unit pairings for it. In cold weather it still delivers 39,000 BTU/h at 5°F — 103% of its 47°F output, well above the 76% median across the 308 models we track (better than 96% of them). Its HSPF2 of 10.3 is higher than 80% of models in our database, and its best certified SEER2 of 18 beats 53%.

Our take in 30 seconds

Best for: cold and very cold climates

Strengths

  • Keeps 103% of its heat at 5°F, so backup heat rarely runs
  • Heating efficiency (HSPF2 10.3) beats 80% of models
  • Variable-speed compressor: quieter, steadier temperatures and better humidity control
  • Uses newer, lower-impact R-454B refrigerant

Good to know

  • No notable drawbacks in the certified data.
Est. yearly cost
$1,527
U.S. average rates
SEER2
15.8–18
Cooling efficiency
HSPF2
10.3
Top 20% heating efficiency
Heat kept at 5°F
103%
Median is 76%
Advertisement

Running-cost calculator

Pre-filled with EIA prices · edit any field
Estimated annual cost
—
Heating
—
Cooling
—

Uses the base certified SEER2 (15.8) and HSPF2 (10.3). Assumes the unit is correctly sized. How we calculate.

Heating capacity as it gets colder

A heat pump's output falls as outdoor temperature drops. This is the certified heat output of the Bryant 37MUHAQ36AA3 at the three ENERGY STAR test temperatures (cooling capacity is 36,000 BTU/h for reference).

47°F
38,000 BTU/h
17°F
33,000 BTU/h
5°F
39,000 BTU/h

Retention at 17°F: 87% · at 5°F: 103%. Learn how to use these numbers in our cold-climate guide.

Estimated running cost in every state

Same unit, very different bills: from about $919 a year in Louisiana to $3,373 in Maine, driven by local electricity prices and how much heating or cooling the climate needs. Click a column to sort.

StatePriceHeatingCoolingTotal / yr
Louisiana12.87¢$332$586$919
Washington14.63¢$918$117$1,034
Florida14.99¢$249$820$1,069
Mississippi14.43¢$479$592$1,071
Nevada12.72¢$563$522$1,085
Tennessee13.42¢$693$398$1,091
Oregon15.92¢$940$163$1,103
Arizona15.05¢$389$754$1,143
North Carolina14.95¢$717$443$1,160
Kentucky13.80¢$815$346$1,160
Arkansas14.37¢$689$491$1,180
Utah13.31¢$933$273$1,206
South Carolina15.76¢$640$575$1,214
Georgia15.90¢$645$580$1,225
Idaho13.37¢$1,036$213$1,249
Texas15.91¢$528$725$1,253
Alabama16.33¢$663$595$1,258
Oklahoma14.82¢$765$507$1,272
New Mexico16.51¢$914$376$1,290
Nebraska13.54¢$1,049$278$1,327
West Virginia16.31¢$1,083$297$1,380
Missouri16.02¢$1,005$402$1,406
Kansas15.47¢$1,027$388$1,415
Virginia17.64¢$976$442$1,418
Wyoming14.43¢$1,331$164$1,495
Colorado17.17¢$1,267$274$1,541
North Dakota13.31¢$1,424$136$1,561
Indiana17.02¢$1,256$330$1,585
Montana15.57¢$1,436$160$1,596
Delaware18.70¢$1,173$426$1,599
South Dakota15.15¢$1,397$224$1,622
California29.75¢$988$678$1,666
Iowa17.06¢$1,448$292$1,739
Ohio19.38¢$1,430$353$1,783
Maryland21.40¢$1,342$488$1,830
Illinois19.32¢$1,497$352$1,849
Minnesota17.20¢$1,713$216$1,929
Pennsylvania21.77¢$1,606$397$2,003
Wisconsin19.41¢$1,790$265$2,056
New Jersey24.61¢$1,634$505$2,139
District of Columbia25.98¢$1,534$651$2,185
Michigan22.99¢$2,036$314$2,350
Connecticut24.51¢$1,989$363$2,352
Vermont23.84¢$2,287$244$2,531
Rhode Island28.18¢$2,287$385$2,672
New York28.65¢$2,325$424$2,750
New Hampshire27.64¢$2,549$315$2,864
Hawaii47.18¢$87$2,795$2,882
Massachusetts30.48¢$2,586$417$3,003
Alaska29.41¢$3,255$67$3,322
Maine32.11¢$3,080$293$3,373
Advertisement

Same equipment sold under other brands

These listings share the same certifying manufacturer (Carrier Corporation) and identical certified capacities and efficiency ratings, so they are almost certainly the same hardware with a different badge. If you get quotes for any of them, you are comparing installation price and warranty, not equipment. How rebadging works.

  • Carrier 37MUHAQ36AA3
  • Midea 37MUHAQ36AA3
  • Payne 37MUHAQ36AA3
  • Weathermaker 37MUHAQ36AA3

Plus 13 more identical listings in the ENERGY STAR database.

Similar-size alternatives

Other ducted split system units within ±15% of this model's cooling capacity, sorted by efficiency. Cost difference is versus the Bryant 37MUHAQ36AA3 at U.S.-average rates.

ModelCooling BTU/hSEER2HSPF25°F keptEst. yearly cost
Ruud UP19AY36AJVC34,20019–211087%$1,353 (−$174)Compare
Daikin DH9VSA361CA*34,20016.9–2110100%$1,398 (−$129)Compare
Panasonic CU-HM36BAHU36,00015.6–17.410.3103%$1,533 (+$6)Compare
MrCool CENTRAL-36-HP-C-230B00-O36,00015.2–17.410.3103%$1,545 (+$18)Compare
Midea MO1SE-H36B-2A36,00015.2–1810.3103%$1,545 (+$18)Compare
Gree FXU36HP230V1R32AO34,00016–18.21097%$1,441 (−$86)Compare

Full specifications

BrandBryant
Outdoor model37MUHAQ36AA3
Certified byCarrier Corporation
Product typeDucted split system
CompressorVariable-speed (inverter)
RefrigerantR-454B
Cooling capacity36,000 BTU/h
Nominal size3 tons
SEER2 (certified range)15.8 – 18
EER2 (best)12
HSPF2 (best)10.3
Heating capacity @ 47°F38,000 BTU/h
Heating capacity @ 17°F33,000 BTU/h
Heating capacity @ 5°F39,000 BTU/h
COP @ 5°F1.9
ENERGY STAR cold-climateYes
Certified indoor pairings8
Latest certification2026-09

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), retrieved November 7, 2026. Capacities and HSPF2 are the highest values across certified pairings; confirm your exact system's AHRI reference number with your installer.

Frequently asked questions

How much does the Bryant 37MUHAQ36AA3 cost to run per year?

At the U.S. average residential electricity price of 18.16¢/kWh and typical national heating and cooling hours, we estimate about $1,527 per year ($1,072 heating, $455 cooling). It ranges from about $919 in Louisiana to $3,373 in Maine.

Does the Bryant 37MUHAQ36AA3 work in cold weather?

Yes. It is ENERGY STAR cold-climate certified and delivers 39,000 BTU/h at 5°F, 103% of its 47°F capacity, with a COP of 1.9 at 5°F.

What size is the Bryant 37MUHAQ36AA3?

It is rated at 36,000 BTU/h of cooling, roughly 3 tons, and 38,000 BTU/h of heating at 47°F. Proper sizing should be confirmed with a Manual J load calculation.

Is the Bryant 37MUHAQ36AA3 the same as the Carrier 37MUHAQ36AA3?

Very likely. Both are certified by Carrier Corporation with identical capacities and efficiency ratings in the ENERGY STAR database, which indicates the same equipment sold under different brands.