Carrier heat pump

27VPA936A*030*

Ducted split systemVariable-speed (inverter)ENERGY STAR cold-climateENERGY STAR Most Efficient (some pairings)

The Carrier 27VPA936A*030* is a ducted split system heat pump outdoor unit with a rated cooling capacity of 37,600 BTU/h (about 3 tons) and a variable-speed (inverter) compressor running on R-454B refrigerant. ENERGY STAR lists 367 certified indoor-unit pairings for it. In cold weather it still delivers 26,600 BTU/h at 5°F — 71% of its 47°F output, close to the 76% median across the 308 models we track (better than 39% of them). Its HSPF2 of 9 is higher than 47% of models in our database, and its best certified SEER2 of 18 beats 53%.

Our take in 30 seconds

Best for: mixed climates with occasional hard freezes

Strengths

  • Variable-speed compressor: quieter, steadier temperatures and better humidity control
  • Uses newer, lower-impact R-454B refrigerant
  • Also sold under 16 other badges, so you can compare more quotes for the same unit

Good to know

  • No notable drawbacks in the certified data.
Est. yearly cost
$1,702
U.S. average rates
SEER2
15.2–18
Cooling efficiency
HSPF2
9
Top 53% heating efficiency
Heat kept at 5°F
71%
Median is 76%
Advertisement

Running-cost calculator

Pre-filled with EIA prices · edit any field
Estimated annual cost
—
Heating
—
Cooling
—

Uses the base certified SEER2 (15.2) and HSPF2 (9). Assumes the unit is correctly sized. How we calculate.

Heating capacity as it gets colder

A heat pump's output falls as outdoor temperature drops. This is the certified heat output of the Carrier 27VPA936A*030* at the three ENERGY STAR test temperatures (cooling capacity is 37,600 BTU/h for reference).

47°F
37,400 BTU/h
17°F
37,600 BTU/h
5°F
26,600 BTU/h

Retention at 17°F: 101% · at 5°F: 71%. Learn how to use these numbers in our cold-climate guide.

Estimated running cost in every state

Same unit, very different bills: from about $1,011 a year in Louisiana to $3,787 in Maine, driven by local electricity prices and how much heating or cooling the climate needs. Click a column to sort.

StatePriceHeatingCoolingTotal / yr
Louisiana12.87¢$374$637$1,011
Washington14.63¢$1,034$127$1,160
Florida14.99¢$280$890$1,170
Mississippi14.43¢$540$643$1,182
Nevada12.72¢$634$566$1,201
Tennessee13.42¢$781$432$1,212
Oregon15.92¢$1,059$177$1,236
Arizona15.05¢$438$819$1,257
North Carolina14.95¢$808$481$1,288
Kentucky13.80¢$918$376$1,293
Arkansas14.37¢$776$533$1,310
South Carolina15.76¢$720$624$1,344
Utah13.31¢$1,051$296$1,347
Georgia15.90¢$727$629$1,356
Texas15.91¢$595$787$1,382
Alabama16.33¢$746$646$1,393
Idaho13.37¢$1,167$232$1,398
Oklahoma14.82¢$862$550$1,412
New Mexico16.51¢$1,029$408$1,438
Nebraska13.54¢$1,182$301$1,483
West Virginia16.31¢$1,220$323$1,543
Missouri16.02¢$1,132$436$1,568
Kansas15.47¢$1,157$421$1,578
Virginia17.64¢$1,100$480$1,580
Wyoming14.43¢$1,499$178$1,678
Colorado17.17¢$1,427$297$1,724
North Dakota13.31¢$1,604$148$1,752
Indiana17.02¢$1,415$358$1,772
Delaware18.70¢$1,321$463$1,784
Montana15.57¢$1,618$173$1,791
South Dakota15.15¢$1,574$244$1,818
California29.75¢$1,113$736$1,849
Iowa17.06¢$1,631$317$1,947
Ohio19.38¢$1,611$384$1,994
Maryland21.40¢$1,512$529$2,041
Illinois19.32¢$1,686$382$2,068
Minnesota17.20¢$1,930$234$2,164
Pennsylvania21.77¢$1,809$431$2,240
Wisconsin19.41¢$2,016$288$2,305
New Jersey24.61¢$1,841$548$2,389
District of Columbia25.98¢$1,727$707$2,434
Michigan22.99¢$2,293$341$2,634
Connecticut24.51¢$2,241$394$2,635
Vermont23.84¢$2,576$265$2,841
Rhode Island28.18¢$2,576$418$2,995
New York28.65¢$2,619$461$3,080
Hawaii47.18¢$98$3,034$3,132
New Hampshire27.64¢$2,871$342$3,213
Massachusetts30.48¢$2,913$452$3,366
Alaska29.41¢$3,666$73$3,739
Maine32.11¢$3,469$318$3,787
Advertisement

Same equipment sold under other brands

These listings share the same certifying manufacturer (Carrier Corporation) and identical certified capacities and efficiency ratings, so they are almost certainly the same hardware with a different badge. If you get quotes for any of them, you are comparing installation price and warranty, not equipment. How rebadging works.

  • Bryant 249VAN036**AA*
  • ACiQ N5H9V36*K*AAA*
  • Airquest N5H9V36*K*AAA*
  • Arcoaire N5H9V36*K*AAA*

Plus 12 more identical listings in the ENERGY STAR database.

Similar-size alternatives

Other ducted split system units within ±15% of this model's cooling capacity, sorted by efficiency. Cost difference is versus the Carrier 27VPA936A*030* at U.S.-average rates.

ModelCooling BTU/hSEER2HSPF25°F keptEst. yearly cost
Ruud UP19AY36AJVC34,20019–211087%$1,353 (−$348)Compare
Bryant 37MUHAQ36AA336,00015.8–1810.3103%$1,527 (−$174)Compare
Daikin DH9VSA361CA*34,20016.9–2110100%$1,398 (−$304)Compare
Panasonic CU-HM36BAHU36,00015.6–17.410.3103%$1,533 (−$169)Compare
MrCool CENTRAL-36-HP-C-230B00-O36,00015.2–17.410.3103%$1,545 (−$156)Compare
Midea MO1SE-H36B-2A36,00015.2–1810.3103%$1,545 (−$156)Compare

Full specifications

BrandCarrier
Outdoor model27VPA936A*030*
Certified byCarrier Corporation
Product typeDucted split system
CompressorVariable-speed (inverter)
RefrigerantR-454B
Cooling capacity37,600 BTU/h
Nominal size3 tons
SEER2 (certified range)15.2 – 18
EER2 (best)13.5
HSPF2 (best)9
Heating capacity @ 47°F37,400 BTU/h
Heating capacity @ 17°F37,600 BTU/h
Heating capacity @ 5°F26,600 BTU/h
COP @ 5°F2.18
ENERGY STAR cold-climateYes
Certified indoor pairings367
Latest certification2026-10

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), retrieved November 7, 2026. Capacities and HSPF2 are the highest values across certified pairings; confirm your exact system's AHRI reference number with your installer.

Frequently asked questions

How much does the Carrier 27VPA936A*030* cost to run per year?

At the U.S. average residential electricity price of 18.16¢/kWh and typical national heating and cooling hours, we estimate about $1,702 per year ($1,207 heating, $494 cooling). It ranges from about $1,011 in Louisiana to $3,787 in Maine.

Does the Carrier 27VPA936A*030* work in cold weather?

Yes. It is ENERGY STAR cold-climate certified and delivers 26,600 BTU/h at 5°F, 71% of its 47°F capacity, with a COP of 2.18 at 5°F.

What size is the Carrier 27VPA936A*030*?

It is rated at 37,600 BTU/h of cooling, roughly 3 tons, and 37,400 BTU/h of heating at 47°F. Proper sizing should be confirmed with a Manual J load calculation.

Is the Carrier 27VPA936A*030* the same as the Bryant 249VAN036**AA*?

Very likely. Both are certified by Carrier Corporation with identical capacities and efficiency ratings in the ENERGY STAR database, which indicates the same equipment sold under different brands.

Advertisement