Carrier heat pump

27VNA336A*030*

Ducted split systemVariable-speed (inverter)ENERGY STAR cold-climateENERGY STAR Most Efficient (some pairings)

The Carrier 27VNA336A*030* is a ducted split system heat pump outdoor unit with a rated cooling capacity of 36,000 BTU/h (about 3 tons) and a variable-speed (inverter) compressor running on R-454B refrigerant. ENERGY STAR lists 564 certified indoor-unit pairings for it. In cold weather it still delivers 29,600 BTU/h at 5°F — 75% of its 47°F output, close to the 76% median across the 308 models we track (better than 47% of them). Its HSPF2 of 9.5 is higher than 61% of models in our database, and its best certified SEER2 of 22.5 beats 82%.

Our take in 30 seconds

Best for: mixed climates with occasional hard freezes

Strengths

  • Cooling efficiency up to SEER2 22.5, better than 82% of models
  • Variable-speed compressor: quieter, steadier temperatures and better humidity control
  • Uses newer, lower-impact R-454B refrigerant
  • Also sold under 19 other badges, so you can compare more quotes for the same unit

Good to know

  • Efficiency depends on the indoor unit: SEER2 ranges 18–22.5, so ask which pairing you're quoted
Est. yearly cost
$1,608
U.S. average rates
SEER2
18–22.5
Cooling efficiency
HSPF2
9.5
Top 39% heating efficiency
Heat kept at 5°F
75%
Median is 76%
Advertisement

Running-cost calculator

Pre-filled with EIA prices · edit any field
Estimated annual cost
—
Heating
—
Cooling
—

Uses the base certified SEER2 (18) and HSPF2 (9.5). Assumes the unit is correctly sized. How we calculate.

Heating capacity as it gets colder

A heat pump's output falls as outdoor temperature drops. This is the certified heat output of the Carrier 27VNA336A*030* at the three ENERGY STAR test temperatures (cooling capacity is 36,000 BTU/h for reference).

47°F
39,500 BTU/h
17°F
34,800 BTU/h
5°F
29,600 BTU/h

Retention at 17°F: 88% · at 5°F: 75%. Learn how to use these numbers in our cold-climate guide.

Estimated running cost in every state

Same unit, very different bills: from about $889 a year in Louisiana to $3,728 in Maine, driven by local electricity prices and how much heating or cooling the climate needs. Click a column to sort.

StatePriceHeatingCoolingTotal / yr
Louisiana12.87¢$375$515$889
Florida14.99¢$280$720$1,000
Mississippi14.43¢$540$519$1,059
Nevada12.72¢$635$458$1,093
Arizona15.05¢$438$662$1,100
Tennessee13.42¢$781$349$1,130
Washington14.63¢$1,034$102$1,137
North Carolina14.95¢$808$389$1,197
Oregon15.92¢$1,059$143$1,202
Arkansas14.37¢$777$431$1,208
Kentucky13.80¢$918$304$1,222
South Carolina15.76¢$721$504$1,225
Texas15.91¢$595$636$1,232
Georgia15.90¢$727$509$1,236
Alabama16.33¢$747$523$1,269
Utah13.31¢$1,051$240$1,291
Oklahoma14.82¢$863$445$1,307
Idaho13.37¢$1,167$187$1,355
New Mexico16.51¢$1,030$330$1,360
Nebraska13.54¢$1,182$244$1,426
West Virginia16.31¢$1,221$261$1,482
Missouri16.02¢$1,132$352$1,485
Virginia17.64¢$1,100$388$1,488
Kansas15.47¢$1,158$340$1,498
Wyoming14.43¢$1,500$144$1,644
Colorado17.17¢$1,428$240$1,668
Delaware18.70¢$1,322$374$1,696
Indiana17.02¢$1,415$289$1,705
California29.75¢$1,113$595$1,708
North Dakota13.31¢$1,605$120$1,725
Montana15.57¢$1,618$140$1,759
South Dakota15.15¢$1,575$197$1,772
Iowa17.06¢$1,631$256$1,887
Ohio19.38¢$1,612$310$1,922
Maryland21.40¢$1,513$428$1,941
Illinois19.32¢$1,687$309$1,996
Minnesota17.20¢$1,931$189$2,120
Pennsylvania21.77¢$1,810$348$2,159
Wisconsin19.41¢$2,018$233$2,251
New Jersey24.61¢$1,842$443$2,285
District of Columbia25.98¢$1,728$572$2,300
Hawaii47.18¢$98$2,453$2,551
Connecticut24.51¢$2,242$319$2,561
Michigan22.99¢$2,294$276$2,570
Vermont23.84¢$2,577$215$2,792
Rhode Island28.18¢$2,578$338$2,916
New York28.65¢$2,621$372$2,993
New Hampshire27.64¢$2,873$276$3,150
Massachusetts30.48¢$2,915$366$3,281
Alaska29.41¢$3,669$59$3,727
Maine32.11¢$3,471$257$3,728
Advertisement

Same equipment sold under other brands

These listings share the same certifying manufacturer (Carrier Corporation) and identical certified capacities and efficiency ratings, so they are almost certainly the same hardware with a different badge. If you get quotes for any of them, you are comparing installation price and warranty, not equipment. How rebadging works.

  • Bryant 293VAN036**AA*
  • ACiQ B5H3V36*K*AAA*
  • Airquest B5H3V36*K*AAA*
  • Arcoaire B5H3V36*K*AAA*

Plus 15 more identical listings in the ENERGY STAR database.

Similar-size alternatives

Other ducted split system units within ±15% of this model's cooling capacity, sorted by efficiency. Cost difference is versus the Carrier 27VNA336A*030* at U.S.-average rates.

ModelCooling BTU/hSEER2HSPF25°F keptEst. yearly cost
Ruud UP19AY36AJVC34,20019–211087%$1,353 (−$254)Compare
Bryant 37MUHAQ36AA336,00015.8–1810.3103%$1,527 (−$81)Compare
Daikin DH9VSA361CA*34,20016.9–2110100%$1,398 (−$210)Compare
Panasonic CU-HM36BAHU36,00015.6–17.410.3103%$1,533 (−$75)Compare
MrCool CENTRAL-36-HP-C-230B00-O36,00015.2–17.410.3103%$1,545 (−$63)Compare
Midea MO1SE-H36B-2A36,00015.2–1810.3103%$1,545 (−$63)Compare

Full specifications

BrandCarrier
Outdoor model27VNA336A*030*
Certified byCarrier Corporation
Product typeDucted split system
CompressorVariable-speed (inverter)
RefrigerantR-454B
Cooling capacity36,000 BTU/h
Nominal size3 tons
SEER2 (certified range)18 – 22.5
EER2 (best)13
HSPF2 (best)9.5
Heating capacity @ 47°F39,500 BTU/h
Heating capacity @ 17°F34,800 BTU/h
Heating capacity @ 5°F29,600 BTU/h
COP @ 5°F2.1
ENERGY STAR cold-climateYes
Certified indoor pairings564
Latest certification2026-07

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), retrieved November 7, 2026. Capacities and HSPF2 are the highest values across certified pairings; confirm your exact system's AHRI reference number with your installer.

Frequently asked questions

How much does the Carrier 27VNA336A*030* cost to run per year?

At the U.S. average residential electricity price of 18.16¢/kWh and typical national heating and cooling hours, we estimate about $1,608 per year ($1,208 heating, $400 cooling). It ranges from about $889 in Louisiana to $3,728 in Maine.

Does the Carrier 27VNA336A*030* work in cold weather?

Yes. It is ENERGY STAR cold-climate certified and delivers 29,600 BTU/h at 5°F, 75% of its 47°F capacity, with a COP of 2.1 at 5°F.

What size is the Carrier 27VNA336A*030*?

It is rated at 36,000 BTU/h of cooling, roughly 3 tons, and 39,500 BTU/h of heating at 47°F. Proper sizing should be confirmed with a Manual J load calculation.

Is the Carrier 27VNA336A*030* the same as the Bryant 293VAN036**AA*?

Very likely. Both are certified by Carrier Corporation with identical capacities and efficiency ratings in the ENERGY STAR database, which indicates the same equipment sold under different brands.