York heat pump

HH860E2S11

Ducted split systemVariable-speed (inverter)ENERGY STAR cold-climateENERGY STAR Most Efficient (some pairings)

The York HH860E2S11 is a ducted split system heat pump outdoor unit with a rated cooling capacity of 54,500 BTU/h (about 4.5 tons) and a variable-speed (inverter) compressor running on R-454B refrigerant. ENERGY STAR lists 370 certified indoor-unit pairings for it. In cold weather it still delivers 40,500 BTU/h at 5°F — 72% of its 47°F output, close to the 76% median across the 308 models we track (better than 43% of them). Its HSPF2 of 9.5 is higher than 61% of models in our database, and its best certified SEER2 of 19 beats 67%.

Our take in 30 seconds

Best for: mixed climates with occasional hard freezes

Strengths

  • Variable-speed compressor: quieter, steadier temperatures and better humidity control
  • Uses newer, lower-impact R-454B refrigerant
  • Also sold under 4 other badges, so you can compare more quotes for the same unit

Good to know

  • Efficiency depends on the indoor unit: SEER2 ranges 15.2–19, so ask which pairing you're quoted
Est. yearly cost
$2,429
U.S. average rates
SEER2
15.2–19
Cooling efficiency
HSPF2
9.5
Top 39% heating efficiency
Heat kept at 5°F
72%
Median is 76%
Advertisement

Running-cost calculator

Pre-filled with EIA prices · edit any field
Estimated annual cost
—
Heating
—
Cooling
—

Uses the base certified SEER2 (15.2) and HSPF2 (9.5). Assumes the unit is correctly sized. How we calculate.

Heating capacity as it gets colder

A heat pump's output falls as outdoor temperature drops. This is the certified heat output of the York HH860E2S11 at the three ENERGY STAR test temperatures (cooling capacity is 54,500 BTU/h for reference).

47°F
56,000 BTU/h
17°F
39,000 BTU/h
5°F
40,500 BTU/h

Retention at 17°F: 70% · at 5°F: 72%. Learn how to use these numbers in our cold-climate guide.

Estimated running cost in every state

Same unit, very different bills: from about $1,454 a year in Louisiana to $5,382 in Maine, driven by local electricity prices and how much heating or cooling the climate needs. Click a column to sort.

StatePriceHeatingCoolingTotal / yr
Louisiana12.87¢$531$923$1,454
Washington14.63¢$1,466$184$1,650
Florida14.99¢$398$1,290$1,688
Mississippi14.43¢$766$931$1,697
Nevada12.72¢$900$821$1,721
Tennessee13.42¢$1,108$626$1,733
Oregon15.92¢$1,502$257$1,758
Arizona15.05¢$621$1,187$1,808
North Carolina14.95¢$1,146$697$1,842
Kentucky13.80¢$1,302$544$1,846
Arkansas14.37¢$1,101$773$1,874
Utah13.31¢$1,491$430$1,920
South Carolina15.76¢$1,022$904$1,926
Georgia15.90¢$1,031$912$1,943
Texas15.91¢$844$1,141$1,985
Idaho13.37¢$1,655$336$1,991
Alabama16.33¢$1,059$937$1,996
Oklahoma14.82¢$1,223$797$2,020
New Mexico16.51¢$1,460$592$2,052
Nebraska13.54¢$1,676$437$2,113
West Virginia16.31¢$1,731$468$2,198
Missouri16.02¢$1,605$632$2,237
Kansas15.47¢$1,641$610$2,252
Virginia17.64¢$1,560$696$2,255
Wyoming14.43¢$2,127$259$2,385
Colorado17.17¢$2,024$431$2,455
North Dakota13.31¢$2,275$215$2,490
Indiana17.02¢$2,007$519$2,525
Delaware18.70¢$1,874$670$2,544
Montana15.57¢$2,295$251$2,546
South Dakota15.15¢$2,233$353$2,586
California29.75¢$1,578$1,067$2,645
Iowa17.06¢$2,313$459$2,772
Ohio19.38¢$2,285$556$2,841
Maryland21.40¢$2,145$767$2,912
Illinois19.32¢$2,392$554$2,946
Minnesota17.20¢$2,738$339$3,077
Pennsylvania21.77¢$2,567$624$3,191
Wisconsin19.41¢$2,860$418$3,278
New Jersey24.61¢$2,611$794$3,405
District of Columbia25.98¢$2,450$1,025$3,475
Michigan22.99¢$3,252$495$3,747
Connecticut24.51¢$3,179$571$3,750
Vermont23.84¢$3,654$385$4,038
Rhode Island28.18¢$3,655$606$4,261
New York28.65¢$3,715$668$4,383
Hawaii47.18¢$139$4,398$4,537
New Hampshire27.64¢$4,073$496$4,569
Massachusetts30.48¢$4,132$656$4,788
Alaska29.41¢$5,201$105$5,306
Maine32.11¢$4,921$461$5,382
Advertisement

Same equipment sold under other brands

These listings share the same certifying manufacturer (Johnson Controls, Inc.) and identical certified capacities and efficiency ratings, so they are almost certainly the same hardware with a different badge. If you get quotes for any of them, you are comparing installation price and warranty, not equipment. How rebadging works.

  • Champion HH860E2S11
  • Coleman HH860E2S11
  • Fraser-Johnston HH860E2S11
  • Luxaire HH860E2S11

Similar-size alternatives

Other ducted split system units within ±15% of this model's cooling capacity, sorted by efficiency. Cost difference is versus the York HH860E2S11 at U.S.-average rates.

ModelCooling BTU/hSEER2HSPF25°F keptEst. yearly cost
Gree GUD60W2/NHE-D(U)53,00016–1910.5100%$2,156 (−$273)Compare
Heil B5H3V48*K*AAA*46,50020–239.576%$1,963 (−$466)Compare
Tempstar T5H3V48*K*AAA*46,50019.5–239.572%$2,113 (−$316)Compare
Rheem RD18AY60AJVC52,00016–181066%$2,393 (−$36)Compare
Carrier 27VPA948A*030*49,50015.2–191075%$2,249 (−$180)Compare
Bosch BOVA-60MTB-M19E53,50015.2–1910100%$2,301 (−$128)Compare

Full specifications

BrandYork
Outdoor modelHH860E2S11
Certified byJohnson Controls, Inc.
Product typeDucted split system
CompressorVariable-speed (inverter)
RefrigerantR-454B
Cooling capacity54,500 BTU/h
Nominal size4.5 tons
SEER2 (certified range)15.2 – 19
EER2 (best)12
HSPF2 (best)9.5
Heating capacity @ 47°F56,000 BTU/h
Heating capacity @ 17°F39,000 BTU/h
Heating capacity @ 5°F40,500 BTU/h
COP @ 5°F2.24
ENERGY STAR cold-climateYes
Certified indoor pairings370
Latest certification2026-10

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), retrieved November 7, 2026. Capacities and HSPF2 are the highest values across certified pairings; confirm your exact system's AHRI reference number with your installer.

Frequently asked questions

How much does the York HH860E2S11 cost to run per year?

At the U.S. average residential electricity price of 18.16¢/kWh and typical national heating and cooling hours, we estimate about $2,429 per year ($1,713 heating, $716 cooling). It ranges from about $1,454 in Louisiana to $5,382 in Maine.

Does the York HH860E2S11 work in cold weather?

Yes. It is ENERGY STAR cold-climate certified and delivers 40,500 BTU/h at 5°F, 72% of its 47°F capacity, with a COP of 2.24 at 5°F.

What size is the York HH860E2S11?

It is rated at 54,500 BTU/h of cooling, roughly 4.5 tons, and 56,000 BTU/h of heating at 47°F. Proper sizing should be confirmed with a Manual J load calculation.

Is the York HH860E2S11 the same as the Champion HH860E2S11?

Very likely. Both are certified by Johnson Controls, Inc. with identical capacities and efficiency ratings in the ENERGY STAR database, which indicates the same equipment sold under different brands.

Advertisement