Mitsubishi Electric heat pump

PUZ-AH24NL2***

Mini-split / multi-splitVariable-speed (inverter)ENERGY STAR Most Efficient (some pairings)

The Mitsubishi Electric PUZ-AH24NL2*** is a mini-split / multi-split heat pump outdoor unit with a rated cooling capacity of 24,000 BTU/h (about 2 tons) and a variable-speed (inverter) compressor running on R-454B refrigerant. ENERGY STAR lists 9 certified indoor-unit pairings for it. In cold weather it still delivers 13,500 BTU/h at 5°F — 52% of its 47°F output, below the 76% median across the 308 models we track (better than 17% of them). Its HSPF2 of 9.8 is higher than 66% of models in our database, and its best certified SEER2 of 22.6 beats 82%.

Our take in 30 seconds

Best for: hot and mild climates

Strengths

  • Cooling efficiency up to SEER2 22.6, better than 82% of models
  • Variable-speed compressor: quieter, steadier temperatures and better humidity control
  • Uses newer, lower-impact R-454B refrigerant

Good to know

  • Only 52% of its heat output remains at 5°F; plan on backup heat in hard freezes
  • Efficiency depends on the indoor unit: SEER2 ranges 17.8–22.6, so ask which pairing you're quoted
Est. yearly cost
$1,040
U.S. average rates
SEER2
17.8–22.6
Cooling efficiency
HSPF2
9.8
Top 34% heating efficiency
Heat kept at 5°F
52%
Median is 76%
Advertisement

Running-cost calculator

Pre-filled with EIA prices · edit any field
Estimated annual cost
—
Heating
—
Cooling
—

Uses the base certified SEER2 (17.8) and HSPF2 (9.8). Assumes the unit is correctly sized. How we calculate.

Heating capacity as it gets colder

A heat pump's output falls as outdoor temperature drops. This is the certified heat output of the Mitsubishi Electric PUZ-AH24NL2*** at the three ENERGY STAR test temperatures (cooling capacity is 24,000 BTU/h for reference).

47°F
26,000 BTU/h
17°F
15,700 BTU/h
5°F
13,500 BTU/h

Retention at 17°F: 60% · at 5°F: 52%. Learn how to use these numbers in our cold-climate guide.

Estimated running cost in every state

Same unit, very different bills: from about $586 a year in Louisiana to $2,388 in Maine, driven by local electricity prices and how much heating or cooling the climate needs. Click a column to sort.

StatePriceHeatingCoolingTotal / yr
Louisiana12.87¢$239$347$586
Florida14.99¢$179$485$664
Mississippi14.43¢$345$350$695
Nevada12.72¢$405$309$714
Arizona15.05¢$280$446$726
Washington14.63¢$660$69$729
Tennessee13.42¢$498$235$734
Oregon15.92¢$676$97$772
North Carolina14.95¢$516$262$778
Arkansas14.37¢$496$291$786
Kentucky13.80¢$586$205$790
South Carolina15.76¢$460$340$800
Georgia15.90¢$464$343$807
Texas15.91¢$380$429$809
Alabama16.33¢$477$352$829
Utah13.31¢$671$162$832
Oklahoma14.82¢$550$300$850
Idaho13.37¢$745$126$871
New Mexico16.51¢$657$223$880
Nebraska13.54¢$754$164$919
West Virginia16.31¢$779$176$955
Missouri16.02¢$723$238$960
Virginia17.64¢$702$262$964
Kansas15.47¢$739$229$968
Wyoming14.43¢$957$97$1,054
Colorado17.17¢$911$162$1,073
Delaware18.70¢$843$252$1,096
Indiana17.02¢$903$195$1,098
North Dakota13.31¢$1,024$81$1,105
California29.75¢$710$401$1,111
Montana15.57¢$1,033$94$1,127
South Dakota15.15¢$1,005$133$1,138
Iowa17.06¢$1,041$173$1,214
Ohio19.38¢$1,028$209$1,237
Maryland21.40¢$965$289$1,254
Illinois19.32¢$1,076$208$1,285
Minnesota17.20¢$1,232$128$1,360
Pennsylvania21.77¢$1,155$235$1,390
Wisconsin19.41¢$1,287$157$1,444
New Jersey24.61¢$1,175$299$1,474
District of Columbia25.98¢$1,103$385$1,488
Connecticut24.51¢$1,431$215$1,645
Michigan22.99¢$1,464$186$1,650
Hawaii47.18¢$63$1,654$1,717
Vermont23.84¢$1,644$145$1,789
Rhode Island28.18¢$1,645$228$1,873
New York28.65¢$1,672$251$1,923
New Hampshire27.64¢$1,833$186$2,020
Massachusetts30.48¢$1,860$247$2,106
Alaska29.41¢$2,341$40$2,380
Maine32.11¢$2,215$173$2,388
Advertisement

Similar-size alternatives

Other mini-split / multi-split units within ±15% of this model's cooling capacity, sorted by efficiency. Cost difference is versus the Mitsubishi Electric PUZ-AH24NL2*** at U.S.-average rates.

ModelCooling BTU/hSEER2HSPF25°F keptEst. yearly cost
Senville SENA-24HF-OG24,00019–2113.583%$876 (−$164)Compare
Senville SENA/24HF/OQ24,00019.2–21.511.593%$982 (−$58)Compare
Pioneer YN024GMFI22RPE24,00019–21.511.280%$901 (−$139)Compare
Hisense AOU-24U3T25U24,00019–2010.5100%$916 (−$124)Compare
Pioneer YN024GLSI24RPG23,00019–2310.476%$940 (−$100)Compare
Mitsubishi Electric PUZ-AK24NLHZ2***24,00017–22.810.8100%$982 (−$59)Compare

Full specifications

BrandMitsubishi Electric
Outdoor modelPUZ-AH24NL2***
Certified byMitsubishi Electric U.S. HVAC Division
Product typeMini-split / multi-split
CompressorVariable-speed (inverter)
RefrigerantR-454B
Cooling capacity24,000 BTU/h
Nominal size2 tons
SEER2 (certified range)17.8 – 22.6
EER2 (best)13.2
HSPF2 (best)9.8
Heating capacity @ 47°F26,000 BTU/h
Heating capacity @ 17°F15,700 BTU/h
Heating capacity @ 5°F13,500 BTU/h
COP @ 5°F2.1
ENERGY STAR cold-climateNo
Certified indoor pairings9
Latest certification2026-08

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), retrieved November 7, 2026. Capacities and HSPF2 are the highest values across certified pairings; confirm your exact system's AHRI reference number with your installer.

Frequently asked questions

How much does the Mitsubishi Electric PUZ-AH24NL2*** cost to run per year?

At the U.S. average residential electricity price of 18.16¢/kWh and typical national heating and cooling hours, we estimate about $1,040 per year ($771 heating, $269 cooling). It ranges from about $586 in Louisiana to $2,388 in Maine.

Does the Mitsubishi Electric PUZ-AH24NL2*** work in cold weather?

It is not ENERGY STAR cold-climate certified. It delivers 13,500 BTU/h at 5°F (52% of its 47°F capacity), so in very cold climates expect more reliance on backup heat.

What size is the Mitsubishi Electric PUZ-AH24NL2***?

It is rated at 24,000 BTU/h of cooling, roughly 2 tons, and 26,000 BTU/h of heating at 47°F. Proper sizing should be confirmed with a Manual J load calculation.

Advertisement