Lennox heat pump

EL18KSLV-024-230A**

Ducted split systemVariable-speed (inverter)ENERGY STAR cold-climateENERGY STAR Most Efficient (some pairings)

The Lennox EL18KSLV-024-230A** is a ducted split system heat pump outdoor unit with a rated cooling capacity of 24,200 BTU/h (about 2 tons) and a variable-speed (inverter) compressor running on R-454B refrigerant. ENERGY STAR lists 205 certified indoor-unit pairings for it. In cold weather it still delivers 23,400 BTU/h at 5°F — 94% of its 47°F output, well above the 76% median across the 308 models we track (better than 80% of them). Its HSPF2 of 10 is higher than 77% of models in our database, and its best certified SEER2 of 18.5 beats 58%.

Our take in 30 seconds

Best for: cold and very cold climates

Strengths

  • Keeps 94% of its heat at 5°F, so backup heat rarely runs
  • Heating efficiency (HSPF2 10) beats 77% of models
  • Variable-speed compressor: quieter, steadier temperatures and better humidity control
  • Uses newer, lower-impact R-454B refrigerant

Good to know

  • Efficiency depends on the indoor unit: SEER2 ranges 15.2–18.5, so ask which pairing you're quoted
Est. yearly cost
$1,039
U.S. average rates
SEER2
15.2–18.5
Cooling efficiency
HSPF2
10
Top 23% heating efficiency
Heat kept at 5°F
94%
Median is 76%
Advertisement

Running-cost calculator

Pre-filled with EIA prices · edit any field
Estimated annual cost
—
Heating
—
Cooling
—

Uses the base certified SEER2 (15.2) and HSPF2 (10). Assumes the unit is correctly sized. How we calculate.

Heating capacity as it gets colder

A heat pump's output falls as outdoor temperature drops. This is the certified heat output of the Lennox EL18KSLV-024-230A** at the three ENERGY STAR test temperatures (cooling capacity is 24,200 BTU/h for reference).

47°F
24,800 BTU/h
17°F
20,200 BTU/h
5°F
23,400 BTU/h

Retention at 17°F: 81% · at 5°F: 94%. Learn how to use these numbers in our cold-climate guide.

Estimated running cost in every state

Same unit, very different bills: from about $633 a year in Louisiana to $2,275 in Maine, driven by local electricity prices and how much heating or cooling the climate needs. Click a column to sort.

StatePriceHeatingCoolingTotal / yr
Louisiana12.87¢$223$410$633
Washington14.63¢$617$82$698
Mississippi14.43¢$322$414$736
Florida14.99¢$167$573$740
Nevada12.72¢$379$365$743
Tennessee13.42¢$466$278$744
Oregon15.92¢$632$114$746
Arizona15.05¢$261$527$788
Kentucky13.80¢$548$242$789
North Carolina14.95¢$482$309$791
Arkansas14.37¢$463$343$806
Utah13.31¢$627$191$818
South Carolina15.76¢$430$401$831
Georgia15.90¢$434$405$839
Idaho13.37¢$696$149$845
Alabama16.33¢$445$416$861
Texas15.91¢$355$507$862
Oklahoma14.82¢$515$354$868
New Mexico16.51¢$614$263$877
Nebraska13.54¢$705$194$899
West Virginia16.31¢$728$208$936
Missouri16.02¢$675$281$956
Kansas15.47¢$691$271$962
Virginia17.64¢$656$309$965
Wyoming14.43¢$895$115$1,010
Colorado17.17¢$852$191$1,043
North Dakota13.31¢$957$95$1,053
Indiana17.02¢$844$230$1,075
Montana15.57¢$965$112$1,077
Delaware18.70¢$788$298$1,086
South Dakota15.15¢$939$157$1,096
California29.75¢$664$474$1,138
Iowa17.06¢$973$204$1,177
Ohio19.38¢$961$247$1,208
Maryland21.40¢$902$341$1,243
Illinois19.32¢$1,006$246$1,252
Minnesota17.20¢$1,152$151$1,302
Pennsylvania21.77¢$1,080$277$1,357
Wisconsin19.41¢$1,203$185$1,389
New Jersey24.61¢$1,099$353$1,451
District of Columbia25.98¢$1,031$455$1,486
Michigan22.99¢$1,368$220$1,588
Connecticut24.51¢$1,337$254$1,591
Vermont23.84¢$1,537$171$1,708
Rhode Island28.18¢$1,538$269$1,807
New York28.65¢$1,563$296$1,860
New Hampshire27.64¢$1,714$220$1,934
Hawaii47.18¢$59$1,953$2,012
Massachusetts30.48¢$1,739$291$2,030
Alaska29.41¢$2,188$47$2,235
Maine32.11¢$2,070$204$2,275
Advertisement

Similar-size alternatives

Other ducted split system units within ±15% of this model's cooling capacity, sorted by efficiency. Cost difference is versus the Lennox EL18KSLV-024-230A** at U.S.-average rates.

ModelCooling BTU/hSEER2HSPF25°F keptEst. yearly cost
Carrier 27VNA324A*030*23,80018–2310.582%$1,044 (+$6)Compare
Rheem RP19AY24AJVC22,80020–211081%$925 (−$114)Compare
Trane 5TWR7024A124,00015.2–17.11179%$907 (−$132)Compare
Trane 5TWX7024A124,00015.2–181179%$907 (−$132)Compare
Bryant 37MUHAQ24AA324,00016–18.710.586%$991 (−$47)Compare
ACiQ ACIQ-24-HPD24,00016–18.610.583%$1,019 (−$20)Compare

Full specifications

BrandLennox
Outdoor modelEL18KSLV-024-230A**
Certified byLennox Industries
Product typeDucted split system
CompressorVariable-speed (inverter)
RefrigerantR-454B
Cooling capacity24,200 BTU/h
Nominal size2 tons
SEER2 (certified range)15.2 – 18.5
EER2 (best)12.3
HSPF2 (best)10
Heating capacity @ 47°F24,800 BTU/h
Heating capacity @ 17°F20,200 BTU/h
Heating capacity @ 5°F23,400 BTU/h
COP @ 5°F1.85
ENERGY STAR cold-climateYes
Certified indoor pairings205
Latest certification2026-09

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), retrieved November 7, 2026. Capacities and HSPF2 are the highest values across certified pairings; confirm your exact system's AHRI reference number with your installer.

Frequently asked questions

How much does the Lennox EL18KSLV-024-230A** cost to run per year?

At the U.S. average residential electricity price of 18.16¢/kWh and typical national heating and cooling hours, we estimate about $1,039 per year ($721 heating, $318 cooling). It ranges from about $633 in Louisiana to $2,275 in Maine.

Does the Lennox EL18KSLV-024-230A** work in cold weather?

Yes. It is ENERGY STAR cold-climate certified and delivers 23,400 BTU/h at 5°F, 94% of its 47°F capacity, with a COP of 1.85 at 5°F.

What size is the Lennox EL18KSLV-024-230A**?

It is rated at 24,200 BTU/h of cooling, roughly 2 tons, and 24,800 BTU/h of heating at 47°F. Proper sizing should be confirmed with a Manual J load calculation.

Advertisement