Fujitsu heat pump

FOP1530TJAZNA

Ducted split systemTwo-stageENERGY STAR cold-climate

The Fujitsu FOP1530TJAZNA is a ducted split system heat pump outdoor unit with a rated cooling capacity of 28,400 BTU/h (about 2.5 tons) and a two-stage compressor running on R-410A refrigerant. ENERGY STAR lists 8 certified indoor-unit pairings for it. In cold weather it still delivers 16,100 BTU/h at 5°F — 57% of its 47°F output, below the 76% median across the 308 models we track (better than 29% of them). Its HSPF2 of 8.1 is higher than 17% of models in our database, and its best certified SEER2 of 16 beats 18%.

Our take in 30 seconds

Best for: mild climates or homes with backup heat

Strengths

  • Meets ENERGY STAR efficiency requirements.

Good to know

  • Only 57% of its heat output remains at 5°F; plan on backup heat in hard freezes
  • Heating efficiency (HSPF2 8.1) is in the lower third of models
  • Uses R-410A, a refrigerant being phased down; future service may cost more
Est. yearly cost
$1,392
U.S. average rates
SEER2
15.2–16
Cooling efficiency
HSPF2
8.1
Top 83% heating efficiency
Heat kept at 5°F
57%
Median is 76%
Advertisement

Running-cost calculator

Pre-filled with EIA prices · edit any field
Estimated annual cost
—
Heating
—
Cooling
—

Uses the base certified SEER2 (15.2) and HSPF2 (8.1). Assumes the unit is correctly sized. How we calculate.

Heating capacity as it gets colder

A heat pump's output falls as outdoor temperature drops. This is the certified heat output of the Fujitsu FOP1530TJAZNA at the three ENERGY STAR test temperatures (cooling capacity is 28,400 BTU/h for reference).

47°F
28,400 BTU/h
17°F
20,200 BTU/h
5°F
16,100 BTU/h

Retention at 17°F: 71% · at 5°F: 57%. Learn how to use these numbers in our cold-climate guide.

Estimated running cost in every state

Same unit, very different bills: from about $797 a year in Louisiana to $3,167 in Maine, driven by local electricity prices and how much heating or cooling the climate needs. Click a column to sort.

StatePriceHeatingCoolingTotal / yr
Louisiana12.87¢$316$481$797
Florida14.99¢$237$672$909
Mississippi14.43¢$455$485$941
Nevada12.72¢$535$428$963
Washington14.63¢$872$96$968
Tennessee13.42¢$659$326$985
Arizona15.05¢$369$619$988
Oregon15.92¢$893$134$1,027
North Carolina14.95¢$681$363$1,045
Arkansas14.37¢$655$403$1,058
Kentucky13.80¢$774$284$1,058
South Carolina15.76¢$608$471$1,079
Georgia15.90¢$613$475$1,089
Texas15.91¢$502$595$1,097
Utah13.31¢$887$224$1,110
Alabama16.33¢$630$488$1,118
Oklahoma14.82¢$727$415$1,143
Idaho13.37¢$984$175$1,159
New Mexico16.51¢$868$308$1,177
Nebraska13.54¢$997$228$1,225
West Virginia16.31¢$1,029$244$1,273
Missouri16.02¢$955$329$1,284
Virginia17.64¢$928$363$1,290
Kansas15.47¢$976$318$1,294
Wyoming14.43¢$1,265$135$1,400
Colorado17.17¢$1,204$225$1,429
Indiana17.02¢$1,194$270$1,464
Delaware18.70¢$1,115$349$1,464
North Dakota13.31¢$1,353$112$1,465
California29.75¢$939$556$1,495
Montana15.57¢$1,365$131$1,496
South Dakota15.15¢$1,328$184$1,512
Iowa17.06¢$1,376$239$1,615
Ohio19.38¢$1,359$290$1,649
Maryland21.40¢$1,276$400$1,675
Illinois19.32¢$1,423$289$1,711
Minnesota17.20¢$1,628$177$1,805
Pennsylvania21.77¢$1,527$325$1,852
Wisconsin19.41¢$1,701$218$1,919
New Jersey24.61¢$1,553$414$1,967
District of Columbia25.98¢$1,457$534$1,991
Connecticut24.51¢$1,891$298$2,188
Michigan22.99¢$1,935$258$2,192
Vermont23.84¢$2,173$200$2,374
Hawaii47.18¢$83$2,292$2,375
Rhode Island28.18¢$2,174$316$2,490
New York28.65¢$2,210$348$2,558
New Hampshire27.64¢$2,423$258$2,681
Massachusetts30.48¢$2,458$342$2,800
Alaska29.41¢$3,093$55$3,148
Maine32.11¢$2,927$240$3,167
Advertisement

Similar-size alternatives

Other ducted split system units within ±15% of this model's cooling capacity, sorted by efficiency. Cost difference is versus the Fujitsu FOP1530TJAZNA at U.S.-average rates.

ModelCooling BTU/hSEER2HSPF25°F keptEst. yearly cost
Payne 37MUHAQ30AA330,00015.3–17.510.898%$1,306 (−$86)Compare
Midea MO1HE-H30B-2A30,00015.2–17.510.898%$1,309 (−$83)Compare
MrCool CENTRAL-30-HP-C-230B00-O30,00015.6–16.81096%$1,372 (−$20)Compare
Panasonic CU-HM30BAHU30,00015.3–16.81096%$1,380 (−$12)Compare
Carrier 27VPA924A*030*25,40015.2–19.51086%$1,083 (−$309)Compare
Lennox EL18KSLV-024-230A**24,20015.2–18.51094%$1,039 (−$353)Compare

Full specifications

BrandFujitsu
Outdoor modelFOP1530TJAZNA
Certified byFujitsu General America, Inc.
Product typeDucted split system
CompressorTwo-stage
RefrigerantR-410A
Cooling capacity28,400 BTU/h
Nominal size2.5 tons
SEER2 (certified range)15.2 – 16
EER2 (best)11.7
HSPF2 (best)8.1
Heating capacity @ 47°F28,400 BTU/h
Heating capacity @ 17°F20,200 BTU/h
Heating capacity @ 5°F16,100 BTU/h
COP @ 5°F2.2
ENERGY STAR cold-climateYes
Certified indoor pairings8
Latest certification2026-06

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), retrieved November 7, 2026. Capacities and HSPF2 are the highest values across certified pairings; confirm your exact system's AHRI reference number with your installer.

Frequently asked questions

How much does the Fujitsu FOP1530TJAZNA cost to run per year?

At the U.S. average residential electricity price of 18.16¢/kWh and typical national heating and cooling hours, we estimate about $1,392 per year ($1,019 heating, $373 cooling). It ranges from about $797 in Louisiana to $3,167 in Maine.

Does the Fujitsu FOP1530TJAZNA work in cold weather?

Yes. It is ENERGY STAR cold-climate certified and delivers 16,100 BTU/h at 5°F, 57% of its 47°F capacity, with a COP of 2.2 at 5°F.

What size is the Fujitsu FOP1530TJAZNA?

It is rated at 28,400 BTU/h of cooling, roughly 2.5 tons, and 28,400 BTU/h of heating at 47°F. Proper sizing should be confirmed with a Manual J load calculation.

Advertisement