Senville heat pump

SENA/09HF/OQ

Mini-split / multi-splitVariable-speed (inverter)ENERGY STAR cold-climateENERGY STAR Most Efficient (some pairings)

The Senville SENA/09HF/OQ is a mini-split / multi-split heat pump outdoor unit with a rated cooling capacity of 9,000 BTU/h (about 1 ton) and a variable-speed (inverter) compressor running on R-410A refrigerant. ENERGY STAR lists 5 certified indoor-unit pairings for it. In cold weather it still delivers 10,800 BTU/h at 5°F — 90% of its 47°F output, well above the 76% median across the 308 models we track (better than 75% of them). Its HSPF2 of 12 is higher than 96% of models in our database, and its best certified SEER2 of 28.1 beats 98%.

Our take in 30 seconds

Best for: cold and very cold climates

Strengths

  • Keeps 90% of its heat at 5°F, so backup heat rarely runs
  • Heating efficiency (HSPF2 12) beats 96% of models
  • Cooling efficiency up to SEER2 28.1, better than 98% of models
  • Variable-speed compressor: quieter, steadier temperatures and better humidity control

Good to know

  • Uses R-410A, a refrigerant being phased down; future service may cost more
  • Efficiency depends on the indoor unit: SEER2 ranges 20.2–28.1, so ask which pairing you're quoted
Est. yearly cost
$380
U.S. average rates
SEER2
20.2–28.1
Cooling efficiency
HSPF2
12
Top 4% heating efficiency
Heat kept at 5°F
90%
Median is 76%
Advertisement

Running-cost calculator

Pre-filled with EIA prices · edit any field
Estimated annual cost
—
Heating
—
Cooling
—

Uses the base certified SEER2 (20.2) and HSPF2 (12). Assumes the unit is correctly sized. How we calculate.

Heating capacity as it gets colder

A heat pump's output falls as outdoor temperature drops. This is the certified heat output of the Senville SENA/09HF/OQ at the three ENERGY STAR test temperatures (cooling capacity is 9,000 BTU/h for reference).

47°F
12,000 BTU/h
17°F
10,100 BTU/h
5°F
10,800 BTU/h

Retention at 17°F: 84% · at 5°F: 90%. Learn how to use these numbers in our cold-climate guide.

Estimated running cost in every state

Same unit, very different bills: from about $205 a year in Louisiana to $895 in Alaska, driven by local electricity prices and how much heating or cooling the climate needs. Click a column to sort.

StatePriceHeatingCoolingTotal / yr
Louisiana12.87¢$90$115$205
Florida14.99¢$67$160$228
Mississippi14.43¢$130$116$246
Arizona15.05¢$105$148$253
Nevada12.72¢$153$102$255
Tennessee13.42¢$188$78$266
Washington14.63¢$249$23$272
North Carolina14.95¢$194$87$281
Arkansas14.37¢$187$96$283
Texas15.91¢$143$142$285
South Carolina15.76¢$173$112$286
Oregon15.92¢$255$32$287
Georgia15.90¢$175$113$288
Kentucky13.80¢$221$68$288
Alabama16.33¢$180$116$296
Utah13.31¢$253$53$306
Oklahoma14.82¢$207$99$307
New Mexico16.51¢$248$74$321
Idaho13.37¢$281$42$322
Nebraska13.54¢$284$54$339
Missouri16.02¢$272$79$351
Virginia17.64¢$265$86$351
West Virginia16.31¢$294$58$352
Kansas15.47¢$278$76$354
Wyoming14.43¢$361$32$393
Colorado17.17¢$343$54$397
California29.75¢$268$133$400
Delaware18.70¢$318$83$401
Indiana17.02¢$340$64$405
North Dakota13.31¢$386$27$413
Montana15.57¢$389$31$420
South Dakota15.15¢$379$44$423
Iowa17.06¢$392$57$449
Ohio19.38¢$388$69$457
Maryland21.40¢$364$95$459
Illinois19.32¢$406$69$475
Minnesota17.20¢$464$42$507
Pennsylvania21.77¢$435$78$513
Wisconsin19.41¢$485$52$537
New Jersey24.61¢$443$99$542
District of Columbia25.98¢$416$127$543
Hawaii47.18¢$24$547$570
Connecticut24.51¢$539$71$610
Michigan22.99¢$552$61$613
Vermont23.84¢$620$48$668
Rhode Island28.18¢$620$75$695
New York28.65¢$630$83$713
New Hampshire27.64¢$691$62$753
Massachusetts30.48¢$701$81$783
Maine32.11¢$835$57$892
Alaska29.41¢$882$13$895
Advertisement

Similar-size alternatives

Other mini-split / multi-split units within ±15% of this model's cooling capacity, sorted by efficiency. Cost difference is versus the Senville SENA/09HF/OQ at U.S.-average rates.

ModelCooling BTU/hSEER2HSPF25°F keptEst. yearly cost
Fujitsu AOUH09KTAP19,00033.5–33.514142%$303 (−$77)Compare
Bryant 37MAHAQ09AA39,00020.6–27.513.899%$340 (−$40)Compare
Bryant 37MARAQ09AA39,00019.6–2613.978%$322 (−$58)Compare
Senville SENA-09HF-OG9,00021.4–27.412.596%$363 (−$17)Compare
Mitsubishi Electric SUZ-AA09NL***9,00017.6–21.712.953%$372 (−$7)Compare
Gree GWH09AVDXE-D6DNA1A/O9,10022.3–3011.2108%$357 (−$23)Compare

Full specifications

BrandSenville
Outdoor modelSENA/09HF/OQ
Certified bySenville Air Conditioners
Product typeMini-split / multi-split
CompressorVariable-speed (inverter)
RefrigerantR-410A
Cooling capacity9,000 BTU/h
Nominal size1 ton
SEER2 (certified range)20.2 – 28.1
EER2 (best)16.2
HSPF2 (best)12
Heating capacity @ 47°F12,000 BTU/h
Heating capacity @ 17°F10,100 BTU/h
Heating capacity @ 5°F10,800 BTU/h
COP @ 5°F2
ENERGY STAR cold-climateYes
Certified indoor pairings5
Latest certification2026-06

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), retrieved November 7, 2026. Capacities and HSPF2 are the highest values across certified pairings; confirm your exact system's AHRI reference number with your installer.

Frequently asked questions

How much does the Senville SENA/09HF/OQ cost to run per year?

At the U.S. average residential electricity price of 18.16¢/kWh and typical national heating and cooling hours, we estimate about $380 per year ($291 heating, $89 cooling). It ranges from about $205 in Louisiana to $895 in Alaska.

Does the Senville SENA/09HF/OQ work in cold weather?

Yes. It is ENERGY STAR cold-climate certified and delivers 10,800 BTU/h at 5°F, 90% of its 47°F capacity, with a COP of 2 at 5°F.

What size is the Senville SENA/09HF/OQ?

It is rated at 9,000 BTU/h of cooling, roughly 1 ton, and 12,000 BTU/h of heating at 47°F. Proper sizing should be confirmed with a Manual J load calculation.