Samsung heat pump

AC024FCUPCG

Ducted split systemTwo-stageENERGY STAR cold-climateENERGY STAR Most Efficient (some pairings)

The Samsung AC024FCUPCG is a ducted split system heat pump outdoor unit with a rated cooling capacity of 24,000 BTU/h (about 2 tons) and a two-stage compressor running on R-454B refrigerant. ENERGY STAR lists 5 certified indoor-unit pairings for it. In cold weather it still delivers 23,800 BTU/h at 5°F — 95% of its 47°F output, well above the 76% median across the 308 models we track (better than 82% of them). Its HSPF2 of 8.5 is higher than 33% of models in our database, and its best certified SEER2 of 17 beats 33%.

Our take in 30 seconds

Best for: cold and very cold climates

Strengths

  • Keeps 95% of its heat at 5°F, so backup heat rarely runs
  • Uses newer, lower-impact R-454B refrigerant

Good to know

  • No notable drawbacks in the certified data.
Est. yearly cost
$1,154
U.S. average rates
SEER2
16–17
Cooling efficiency
HSPF2
8.5
Top 67% heating efficiency
Heat kept at 5°F
95%
Median is 76%
Advertisement

Running-cost calculator

Pre-filled with EIA prices · edit any field
Estimated annual cost
—
Heating
—
Cooling
—

Uses the base certified SEER2 (16) and HSPF2 (8.5). Assumes the unit is correctly sized. How we calculate.

Heating capacity as it gets colder

A heat pump's output falls as outdoor temperature drops. This is the certified heat output of the Samsung AC024FCUPCG at the three ENERGY STAR test temperatures (cooling capacity is 24,000 BTU/h for reference).

47°F
25,000 BTU/h
17°F
16,500 BTU/h
5°F
23,800 BTU/h

Retention at 17°F: 66% · at 5°F: 95%. Learn how to use these numbers in our cold-climate guide.

Estimated running cost in every state

Same unit, very different bills: from about $651 a year in Louisiana to $2,648 in Maine, driven by local electricity prices and how much heating or cooling the climate needs. Click a column to sort.

StatePriceHeatingCoolingTotal / yr
Louisiana12.87¢$265$386$651
Florida14.99¢$198$540$738
Mississippi14.43¢$382$390$772
Nevada12.72¢$449$343$792
Arizona15.05¢$310$497$807
Washington14.63¢$732$77$808
Tennessee13.42¢$553$262$814
Oregon15.92¢$749$107$857
North Carolina14.95¢$572$292$863
Arkansas14.37¢$549$323$873
Kentucky13.80¢$649$228$877
South Carolina15.76¢$510$378$888
Georgia15.90¢$514$382$896
Texas15.91¢$421$477$898
Alabama16.33¢$528$392$920
Utah13.31¢$744$180$923
Oklahoma14.82¢$610$333$944
Idaho13.37¢$826$140$966
New Mexico16.51¢$728$248$976
Nebraska13.54¢$836$183$1,019
West Virginia16.31¢$863$196$1,059
Missouri16.02¢$801$264$1,065
Virginia17.64¢$778$291$1,069
Kansas15.47¢$819$255$1,074
Wyoming14.43¢$1,061$108$1,169
Colorado17.17¢$1,010$180$1,190
Delaware18.70¢$935$280$1,216
Indiana17.02¢$1,001$217$1,218
North Dakota13.31¢$1,135$90$1,225
California29.75¢$788$446$1,234
Montana15.57¢$1,145$105$1,250
South Dakota15.15¢$1,114$148$1,262
Iowa17.06¢$1,154$192$1,346
Ohio19.38¢$1,140$233$1,373
Maryland21.40¢$1,070$321$1,391
Illinois19.32¢$1,193$232$1,425
Minnesota17.20¢$1,366$142$1,508
Pennsylvania21.77¢$1,281$261$1,542
Wisconsin19.41¢$1,427$175$1,602
New Jersey24.61¢$1,303$332$1,635
District of Columbia25.98¢$1,223$429$1,651
Connecticut24.51¢$1,586$239$1,825
Michigan22.99¢$1,623$207$1,830
Hawaii47.18¢$69$1,840$1,909
Vermont23.84¢$1,823$161$1,984
Rhode Island28.18¢$1,823$254$2,077
New York28.65¢$1,854$279$2,133
New Hampshire27.64¢$2,032$207$2,240
Massachusetts30.48¢$2,062$274$2,336
Alaska29.41¢$2,595$44$2,639
Maine32.11¢$2,455$193$2,648
Advertisement

Similar-size alternatives

Other ducted split system units within ±15% of this model's cooling capacity, sorted by efficiency. Cost difference is versus the Samsung AC024FCUPCG at U.S.-average rates.

ModelCooling BTU/hSEER2HSPF25°F keptEst. yearly cost
Carrier 27VNA324A*030*23,80018–2310.582%$1,044 (−$110)Compare
Rheem RP19AY24AJVC22,80020–211081%$925 (−$229)Compare
Trane 5TWR7024A124,00015.2–17.11179%$907 (−$247)Compare
Trane 5TWX7024A124,00015.2–181179%$907 (−$247)Compare
Bryant 37MUHAQ24AA324,00016–18.710.586%$991 (−$163)Compare
ACiQ ACIQ-24-HPD24,00016–18.610.583%$1,019 (−$135)Compare

Full specifications

BrandSamsung
Outdoor modelAC024FCUPCG
Certified bySamsung Electronics Co., Ltd.
Product typeDucted split system
CompressorTwo-stage
RefrigerantR-454B
Cooling capacity24,000 BTU/h
Nominal size2 tons
SEER2 (certified range)16 – 17
EER2 (best)11.7
HSPF2 (best)8.5
Heating capacity @ 47°F25,000 BTU/h
Heating capacity @ 17°F16,500 BTU/h
Heating capacity @ 5°F23,800 BTU/h
COP @ 5°F1.94
ENERGY STAR cold-climateYes
Certified indoor pairings5
Latest certification2026-03

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), retrieved November 7, 2026. Capacities and HSPF2 are the highest values across certified pairings; confirm your exact system's AHRI reference number with your installer.

Frequently asked questions

How much does the Samsung AC024FCUPCG cost to run per year?

At the U.S. average residential electricity price of 18.16¢/kWh and typical national heating and cooling hours, we estimate about $1,154 per year ($855 heating, $300 cooling). It ranges from about $651 in Louisiana to $2,648 in Maine.

Does the Samsung AC024FCUPCG work in cold weather?

Yes. It is ENERGY STAR cold-climate certified and delivers 23,800 BTU/h at 5°F, 95% of its 47°F capacity, with a COP of 1.94 at 5°F.

What size is the Samsung AC024FCUPCG?

It is rated at 24,000 BTU/h of cooling, roughly 2 tons, and 25,000 BTU/h of heating at 47°F. Proper sizing should be confirmed with a Manual J load calculation.

Advertisement