Ducted split systemVariable-speed (inverter)ENERGY STAR cold-climateENERGY STAR Most Efficient (some pairings)

The Carrier 27VNA048A*030* is a ducted split system heat pump outdoor unit with a rated cooling capacity of 49,000 BTU/h (about 4 tons) and a variable-speed (inverter) compressor running on R-454B refrigerant. ENERGY STAR lists 376 certified indoor-unit pairings for it. In cold weather it still delivers 37,600 BTU/h at 5°F — 75% of its 47°F output, close to the 76% median across the 308 models we track (better than 48% of them). Its HSPF2 of 9.5 is higher than 61% of models in our database, and its best certified SEER2 of 19.5 beats 69%.

Our take in 30 seconds

Best for: mixed climates with occasional hard freezes

Strengths

  • Variable-speed compressor: quieter, steadier temperatures and better humidity control
  • Uses newer, lower-impact R-454B refrigerant
  • Also sold under 19 other badges, so you can compare more quotes for the same unit

Good to know

  • Efficiency depends on the indoor unit: SEER2 ranges 15.5–19.5, so ask which pairing you're quoted
Est. yearly cost
$2,161
U.S. average rates
SEER2
15.5–19.5
Cooling efficiency
HSPF2
9.5
Top 39% heating efficiency
Heat kept at 5°F
75%
Median is 76%
Advertisement

Running-cost calculator

Pre-filled with EIA prices · edit any field
Estimated annual cost
—
Heating
—
Cooling
—

Uses the base certified SEER2 (15.5) and HSPF2 (9.5). Assumes the unit is correctly sized. How we calculate.

Heating capacity as it gets colder

A heat pump's output falls as outdoor temperature drops. This is the certified heat output of the Carrier 27VNA048A*030* at the three ENERGY STAR test temperatures (cooling capacity is 49,000 BTU/h for reference).

47°F
50,000 BTU/h
17°F
47,500 BTU/h
5°F
37,600 BTU/h

Retention at 17°F: 95% · at 5°F: 75%. Learn how to use these numbers in our cold-climate guide.

Estimated running cost in every state

Same unit, very different bills: from about $1,288 a year in Louisiana to $4,800 in Maine, driven by local electricity prices and how much heating or cooling the climate needs. Click a column to sort.

StatePriceHeatingCoolingTotal / yr
Louisiana12.87¢$474$814$1,288
Washington14.63¢$1,309$162$1,471
Florida14.99¢$355$1,137$1,492
Mississippi14.43¢$684$821$1,505
Nevada12.72¢$803$724$1,527
Tennessee13.42¢$989$552$1,540
Oregon15.92¢$1,341$226$1,567
Arizona15.05¢$554$1,047$1,601
North Carolina14.95¢$1,023$614$1,637
Kentucky13.80¢$1,162$480$1,642
Arkansas14.37¢$983$681$1,665
South Carolina15.76¢$912$797$1,710
Utah13.31¢$1,331$379$1,710
Georgia15.90¢$921$804$1,725
Texas15.91¢$754$1,006$1,760
Alabama16.33¢$945$826$1,771
Idaho13.37¢$1,478$296$1,774
Oklahoma14.82¢$1,092$703$1,795
New Mexico16.51¢$1,303$522$1,825
Nebraska13.54¢$1,497$385$1,882
West Virginia16.31¢$1,545$412$1,958
Missouri16.02¢$1,433$557$1,990
Kansas15.47¢$1,466$538$2,004
Virginia17.64¢$1,393$613$2,006
Wyoming14.43¢$1,899$228$2,127
Colorado17.17¢$1,807$380$2,187
North Dakota13.31¢$2,032$189$2,221
Indiana17.02¢$1,792$457$2,249
Delaware18.70¢$1,673$591$2,264
Montana15.57¢$2,049$221$2,270
South Dakota15.15¢$1,993$311$2,305
California29.75¢$1,409$940$2,350
Iowa17.06¢$2,065$404$2,470
Ohio19.38¢$2,040$490$2,530
Maryland21.40¢$1,915$677$2,591
Illinois19.32¢$2,135$489$2,624
Minnesota17.20¢$2,444$299$2,743
Pennsylvania21.77¢$2,292$551$2,842
Wisconsin19.41¢$2,554$368$2,922
New Jersey24.61¢$2,331$700$3,032
District of Columbia25.98¢$2,188$903$3,091
Michigan22.99¢$2,904$436$3,340
Connecticut24.51¢$2,838$504$3,342
Vermont23.84¢$3,262$339$3,601
Rhode Island28.18¢$3,263$535$3,797
New York28.65¢$3,317$589$3,906
Hawaii47.18¢$124$3,878$4,002
New Hampshire27.64¢$3,637$437$4,074
Massachusetts30.48¢$3,690$578$4,268
Alaska29.41¢$4,644$93$4,737
Maine32.11¢$4,394$406$4,800
Advertisement

Same equipment sold under other brands

These listings share the same certifying manufacturer (Carrier Corporation) and identical certified capacities and efficiency ratings, so they are almost certainly the same hardware with a different badge. If you get quotes for any of them, you are comparing installation price and warranty, not equipment. How rebadging works.

  • Bryant 290VAN048**AA*
  • ACiQ B5H0V48*K*AAA*
  • Airquest B5H0V48*K*AAA*
  • Arcoaire B5H0V48*K*AAA*

Plus 15 more identical listings in the ENERGY STAR database.

Similar-size alternatives

Other ducted split system units within ±15% of this model's cooling capacity, sorted by efficiency. Cost difference is versus the Carrier 27VNA048A*030* at U.S.-average rates.

ModelCooling BTU/hSEER2HSPF25°F keptEst. yearly cost
Ruud UP19AY48AJVC45,50018–191092%$1,827 (−$334)Compare
Gree GUD60W2/NHE-D(U)53,00016–1910.5100%$2,156 (−$5)Compare
Heil B5H3V48*K*AAA*46,50020–239.576%$1,963 (−$198)Compare
Tempstar T5H3V48*K*AAA*46,50019.5–239.572%$2,113 (−$48)Compare
Rheem RD18AY48AJVC43,50016–191088%$1,793 (−$368)Compare
Rheem RD18AY60AJVC52,00016–181066%$2,393 (+$232)Compare

Full specifications

BrandCarrier
Outdoor model27VNA048A*030*
Certified byCarrier Corporation
Product typeDucted split system
CompressorVariable-speed (inverter)
RefrigerantR-454B
Cooling capacity49,000 BTU/h
Nominal size4 tons
SEER2 (certified range)15.5 – 19.5
EER2 (best)10.5
HSPF2 (best)9.5
Heating capacity @ 47°F50,000 BTU/h
Heating capacity @ 17°F47,500 BTU/h
Heating capacity @ 5°F37,600 BTU/h
COP @ 5°F2.2
ENERGY STAR cold-climateYes
Certified indoor pairings376
Latest certification2026-06

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), retrieved November 7, 2026. Capacities and HSPF2 are the highest values across certified pairings; confirm your exact system's AHRI reference number with your installer.

Frequently asked questions

How much does the Carrier 27VNA048A*030* cost to run per year?

At the U.S. average residential electricity price of 18.16¢/kWh and typical national heating and cooling hours, we estimate about $2,161 per year ($1,529 heating, $631 cooling). It ranges from about $1,288 in Louisiana to $4,800 in Maine.

Does the Carrier 27VNA048A*030* work in cold weather?

Yes. It is ENERGY STAR cold-climate certified and delivers 37,600 BTU/h at 5°F, 75% of its 47°F capacity, with a COP of 2.2 at 5°F.

What size is the Carrier 27VNA048A*030*?

It is rated at 49,000 BTU/h of cooling, roughly 4 tons, and 50,000 BTU/h of heating at 47°F. Proper sizing should be confirmed with a Manual J load calculation.

Is the Carrier 27VNA048A*030* the same as the Bryant 290VAN048**AA*?

Very likely. Both are certified by Carrier Corporation with identical capacities and efficiency ratings in the ENERGY STAR database, which indicates the same equipment sold under different brands.

Advertisement